Geared motors are generally used for low-speed high-torque transmission equipment. The purpose of deceleration is to transfer the motor or other high-speed transmission equipment to the gear of the output shaft through a reducer.
Voltage
Volt (V)
220
Rated frequency
Hertz (HZ)
50/60
input power
Watt (W)
14
Working current
Milliamp (mA)
45
noise
Decibel (dB)
35
Insulation class
Grade
E
model
Speed (r / min)
3
5
7.6
10
15
twenty one
30
50
60
100
A
Output torque
Kg / cm
(Kg / cm)
31
26
20
16
10
7.5
5
3
2.5
1.5
B
40
37
27
twenty one
14
11
7
4.2
3.5
2
C
45
40
30
twenty three
15.5
12.5
8
5
4
2.5
A1
45
37
27
twenty one
14
11
7
4.2
3.5
2
B1
40
55
41
31
30
20
10
6
5
3.8
C1
45
60
48
40
36
25
14
7.5
6.8
4.8
Gear reduction
To determine the model of a geared motor, you need to do the following:
1. Determine the running speed of the machine and calculate based on this speed
DC gear motor load
1. Before use, please confirm whether the appearance of the geared motor is damaged and whether there is oil leakage.
2. Check the voltage of the geared motor first. A voltage regulator can be installed when the voltage is unstable.
3. Please confirm whether the specifications of the geared motor purchased are in accordance with the design specifications.
4. Please confirm the fixed base to avoid loosening when running the transmission.
5. If accessories such as sprocket, pulley, coupling, etc. are used, they must be installed in accordance with relevant regulations.
6. The lubricating butter has been installed in the gearbox body, and no need to change the lubricating oil for 12,000 hours.
7. When the geared motor is running, the rated current must not exceed the current value indicated on the motor nameplate.
8, please pay attention to the surrounding temperature, humidity, pH and other issues.
9. If it is not installed, maintained or operated in the correct way, it may cause serious injury to the geared motor.
10. When repairing or disassembling, make sure that the external power supply is completely disengaged from the geared motor.
11. Safety protection devices must be installed to ensure absolute operation safety.
12. The motor needs a ground wire. Please refer to the relevant regulations on power distribution.
13. Please make sure that all installation parts and transmission accessories are fixed before starting the geared motor.
14. If the geared motor is matched with the inverter for low speed transmission, an independent auxiliary cooling fan must be installed.
15. After the single-phase geared motor is powered off, some charges still remain in its capacitor. Please discharge or ground the terminal first. [1]