What Is a Water Control Valve?
Water level control valve is also known as hydraulic water level control valve. The hydraulic water level control valve has the function of automatically opening and closing the pipeline to control the water level. It is suitable for automatic water supply systems of various water towers (pools) in industrial and mining enterprises and civil buildings, and can be used as a circulating water supply control valve for atmospheric boilers.
Water level control valve
- This entry lacks an information bar . Supplementing related content makes the entry more complete and can be quickly upgraded. Hurry up!
- Water level control valve is also known as hydraulic water level control valve. The hydraulic water level control valve has the function of automatically opening and closing the pipeline to control the water level. It is suitable for the automatic water supply system of various water towers (pools) in industrial and mining enterprises and civil buildings, and can be used at normal pressure.
- H142X piston hydraulic water level control valve is a hydraulic control valve that automatically controls the height of the water tank and water tower. When the water surface drops below a preset value,
- When the water level in the pool or water tower drops and the floating ball valve is opened for drainage, there is pressurized water in the water inlet pipe to lift the piston in the valve, the sealing surface opens, and the valve starts water supply. If the sealing surface is closed, the valve stops the water supply.
- Use medium: clean water
- Working pressure: H142X-4T-A, H142X-4-A: 0.05MPa 0.4MPa
- H142X-10-A: 0.05MPa 1MPa
- Medium temperature: 60
- 1. Controlled by hydraulic principle, the structure is novel and reasonable.
- 2. Stable and reliable work. Within the specified operating pressure range, no water hammer impact can be guaranteed.
- 3. Light weight and small size.
- 4. Easy installation and maintenance.
- The valve is vertically fixed on the water inlet pipe, and then the control pipe, the shut-off valve and the float valve are connected and screwed on the valve. The valve inlet and outlet pipe connection flanges H142X-4T-A are 0.6MPa standard flanges; H142X-10-A is a 1MPa standard flange. The diameter of the water inlet pipe should be greater than or equal to the nominal diameter of the valve, and the water outlet should be lower than the float valve. The float valve should be installed more than one meter away from the water pipe; drill a small hole in the water tank above the water level line to prevent direct water return. When in use, the shut-off valve should be fully open. If more than two valves are installed in the same pool, the same level should be maintained. Because the main valve is closed, it is about 30 to 50 seconds after the float valve is closed. Therefore, the water tank must have enough free volume to prevent overflow. To prevent impurities and grit from entering the valve and causing it to malfunction, a filter should be installed before the valve. If it is installed in a groundwater tank, an alarm device should be installed in the underground pump room.
- The hydraulic water level control valve is small in size, easy to install, high in use sensitivity, and small in head loss without water hammer. Because of the small floating ball control, the utilization rate of the water tower can be greatly improved.
- Water level control valve
- H142X Hydraulic Water Level Control Valve Main Dimension Connection Unit: mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- H142X hydraulic water level control valve typical installation diagram (integrated installation)