What are the output doors?

The exit door is designed to allow the residents of the building safely evacuate during the emergency situation. In most countries, the output doors are regulated by local building regulations, which determine how many doors are required and requirements for each departure. In the United States, most building regulations concerning output doors are based on standards developed by the National Fire Protection Association (NFPA). NFPA Standard 101 Stipulates has output doors should be controlled, installed and controlled. NFPA instructions are based on the function of the building and the load of passengers, as well as the presence of dangerous or flammable materials.

According to NFPA 101, the exit doors are not limited to the door that leads out. Instead, each door along the exit road of the building is considered to be the exit door. This includes doors that lead from different rooms to the east, such as the door of the office or corridor that is located throughout the building. Also includes the door leadingTo an output, which often includes a staircase or door in the hall. Finally, the exit doors themselves, which allow passengers to move from the building to the public space, are also considered the exit door.

It is important to understand that NFPA standards are not in themselves by law. However, as soon as they are incorporated into the Building Code, they will become legally binding for architects, suppliers and building managers. Historically, NFPA updates its standards at least every three years, but there is often a delay than the latest version modified by every state or municipality.

The output door must meet specific requirements before the building is approved by the local firefighting marshal or building inspector. All doors for the output must be at least 32 inches (81 cm) or at least 28 inches (71 cm) wide in existing structures. No single output doors can be wider than 48 ”(121 cm), PRoto -greenness and door weight can slow evacuation. The door must also swing in the direction of ascent if the building has more than 50 passengers, or if the building is exposed to a high risk of fire emergency.

In terms of ensuring the exit doors, all locks must be unlocked by means of a single movement from the inside of the room. This means that a separate dead end and the latch are not acceptable because they would require unlocking more than one action. Bilateral dead ends are also unacceptable because they cannot be unlocked at all times. All locking devices must enable the back of the building from the staircase and no chains, screws or bars can be placed when the building is occupied. In many cases, the output device or a "panic stripe" is the best type of hardware to secure the output door, especially in heavily occupied areas.

The exit door is not the same as the fire door. Opening with a fire ranking is designed to reduce the spread of flame flames duringfire. It is equipped with a fire -resistant core and special hardware to ensure that it remains closed and closed during the fire. The exit doors are designed to allow fast and safe output during any type of emergency. They may or may not be evaluated by fire and are used to allow as many people as possible to leave without panic or injury.