What Is Electromagnetic Therapy?

The electromagnetic wave therapeutic instrument is commonly known as the "sacred lamp", and its core component, the TDP therapy board, is made of more than 30 selected elements as a coating. Under the action of temperature, it can produce electromagnetic waves with information and energy of dozens of elements, which has a wide range of comprehensive biological effects on living organisms.

Electromagnetic wave treatment instrument

The electromagnetic wave therapeutic instrument is commonly known as the "sacred lamp", and its core component, the TDP therapy board, is made of more than 30 selected elements as a coating. Under the action of temperature, it can produce electromagnetic waves with information and energy of dozens of elements, which has a wide range of comprehensive biological effects on living organisms.
Chinese name
Electromagnetic wave treatment instrument
Common name
Magic lamp
Core components
TDP treatment board
Are there any side effects
no
Effect
Anti-inflammatory, analgesic, itching, lipid-lowering, etc.
working principle
Generates electromagnetic waves with multiple elemental information energy
After nearly a hundred research institutes, colleges and universities and other units have conducted research and tests, it has been scientifically proven that the electromagnetic wave therapeutic apparatus has: to improve the activity of various enzymes in the body, promote the body's absorption of various deficient elements, repair and unblock microcirculation channels; Stimulate the body's own immune function and disease resistance; promote the body's secretion of enkephalin, and achieve the purpose of sustained analgesia. After more than 20 years of clinical treatments of hundreds of millions of people, the electromagnetic wave therapeutic apparatus has fully shown that the therapeutic effects of anti-inflammatory, analgesic, antipruritic, lipid-lowering, unblocking microcirculation channels, removing deep congestion in the body, promoting epithelial growth, and accelerating wound healing. And without any toxic side effects.
1. The electromagnetic wave therapeutic instrument can effectively promote the accelerated modification of the microcirculation system and improve the blood circulation of the affected part;
2.The electromagnetic wave treatment instrument can enhance the body's disease resistance;
3. The electromagnetic wave therapeutic apparatus can add excretion of enkephalin in patients, and has the effect of durable analgesia;
4. The electromagnetic wave therapy instrument can promote the body's absorption of missing elements.
Through computer application and numerical control technology, multiple multi-step program prescriptions are stored, and each current prescription has different modulations and combinations. It is treated with silicon conductive rubber electrodes, and the operation is simple and safe. Different current prescriptions can be selected according to the patient's condition, with the two electrodes facing each other or juxtaposed with the treatment site. The intensity of the treatment current is tolerated by the patient, generally 0.1 ~ 0.3mA / c. When the electrode is energized, there is tremor, twitching or muscle contraction under the electrode, which is easy to tolerate. Generally, each prescription is treated for 15-20 minutes, once a day, and 7-15 is a course of treatment (the middle of each course, it is suspended for 1 day).
Internal medicine: adult acute, chronic functional diarrhea, chronic bronchitis, coronary heart disease, angina pectoris, rheumatoid arthritis, etc .; gynecology: dysmenorrhea, pelvic inflammatory disease, secondary infertility; pediatrics: infant diarrhea, pediatric pneumonia, neonatal scleroma Disease; neurology: paralysis, neurasthenia, sequelae caused by cerebrovascular accident, etc .; others: neuroseborrheic dermatitis, skin eczema, sinusitis, auricular chondritis; health care: various causes caused by insomnia, fatigue Discomfort, senile multiple discomforts, etc.
A. It has curative effect on cervical spondylosis, intractable diarrhea and enteritis in infants.
B. It has a good promotion effect on congestion, thrombus and hematoma in the body
C. It has strange effects on blood circulation disorders and microcirculation obstacles.
D. It has a good anti-inflammatory and swelling effect on various soft tissue injuries.
E. Patients with rheumatoid arthritis, headache and other diseases have obvious relief or treatment
Connected to 220v voltage, the buzzer sounds, the "power" light is on, and the digital tube displays 00
Set the treatment time: press the "Time" button to set the time, press once to increase 10 minutes, up to 90 minutes, press again to return to 00
Set the temperature: After pressing the "Temperature" button, if the digital tube displays 10, the power is 100%, and then press the display 9, the power is 90%, press it again to reduce the power by 10%, press it all the way to 5, and the power is 50%, then Back, digital tube display 10, power 100%
Press the "On / Off" button, the "Work" indicator light is on, and the countdown starts. When the time is up (00 is displayed), the "Work" light is off, the buzzer beeps three times, and the treatment is over.
Reset "Time" and "Temperature", press "On / Off" to start the next treatment again
In heating treatment, press the "On / Off" button to terminate the treatment
If you do not continue treatment, disconnect the power
1. The irradiation site must be completely exposed during treatment, otherwise it will affect the curative effect.
2. When irradiating the face, take protective measures to avoid eye dryness.
3. The treatment device should be protected from severe vibration, dampness, protection of the surface of the board and high temperature of the irradiation head to avoid burns.
4. After the heating resistance wire is damaged, please replace it in time.
5. In order to ensure the safety of use and prolong the life of the electromagnetic wave therapy instrument, turn off the power immediately after use, to prevent strong vibrations, moisture, and protect the coating layout.
6. The exposed part must be completely exposed, otherwise it will affect the curative effect, but patients should wear colored glasses or goggles when irradiating the face to protect their eyes from the dryness of the eyes. If used on infants, reduce skin temperature.
7. The irradiation distance should not be too close, otherwise skin burns (such as redness or blistering) may easily occur or the paint board may be touched by mistake; adjust the light
Care should also be taken to prevent burns.
8. When the paint board is found to be dark red (about two years later), the board needs to be replaced.
9. Do not allow children to operate the electromagnetic wave therapy device or approach the heated lamp cap.
10. Don't forget to turn the power transfer switch to the position corresponding to the local voltage before turning on the power.
11. When the electromagnetic wave treatment device does not work normally, please check whether the fuse is damaged first. If damaged, use spare parts.