What Is a Cubicle Mount?
1. Small size: The height of the whole machine is only 380-560mm, which minimizes the installation space, and is especially suitable for applications with limited installation volume.
CB series ultra-thin air-conditioning cabinet
Right!
- 1. Small size: The height of the whole machine is only 380-560mm, which minimizes the installation space, and is especially suitable for applications with limited installation volume.
- 2. Low power: The power configuration of the motor is reasonable, energy saving and environmental protection. And there are 220V / 380V two kinds of power to choose from, among them the 220V single-phase motor also has the function of three-speed speed regulation, which can meet the different needs of the fan performance in the application.
- 3. Low noise: The direct drive of the motor is adopted to reduce the mechanical noise. You can also choose sound-absorbing cotton according to customer needs, which can more effectively reduce the noise of the whole machine to meet the requirements of places with higher noise requirements.
- 4. Stable operation: The wind wheel undergoes strict dynamic balance, and the balance accuracy is G4.0.
- 5. Easy maintenance: The cabinet is easy to assemble, and the installation and maintenance are very convenient. The design of the direct drive also makes the maintenance easier.
- 6, the appearance is simple and generous: all parts of the cabinet are made of galvanized steel, with advanced production technology, sturdy and practical, and have certain anti-corrosion performance.
- 1. Operating environment requirements: The medium conveyed by the fan should be a non-corrosive, non-flammable and explosive gas that does not contain viscous substances. The solid particles contained in the medium should not exceed 100 mg / m3. Humidity is between 5% and 98%. Never use it for fume extraction.
- 2. This series of fans are only suitable for systems with a certain resistance. It is strictly forbidden to run for a long time with extremely low resistance or fully open (that is, the inlet and outlet are not connected to the pipeline), otherwise the motor will be damaged due to overload. A short time overload test machine is allowed, but the time of each test machine cannot exceed 3 minutes. When selecting, please carefully calculate the system resistance and check the performance curve of the fan.
- 3. Sound-absorbing cotton is an optional accessory. Please indicate in the order if it is needed.
- 4. The direction of the standard air outlet of this series of fans is straight in and straight out (as shown in the external dimension drawing). If special air outlet is needed, please consult with our company's technical department first.
- 1. Before installation, it is necessary to check in detail whether the parts of the fan are deformed or damaged due to transportation, and whether the parts are tightly connected. If problems are found, they should be adjusted and repaired before installation.
- 2. The foundation for installing the fan should have sufficient strength and stability. The base of the fan should be naturally combined with the foundation plane, and the base must not be forcibly connected. The anchor bolt holes on the body should be used for fastening between the fan and the foundation. Ensure the horizontal position of the fan during installation.
- 3. This series of fans are not allowed to be directly mounted. A boom or support must be installed to install the fans, and the fans should be installed in a horizontal position.
- 4. When installing pipes at the air inlet and outlet of the fan, the pipe interface connected to the fan should be connected by a hose, and the weight of the pipe cannot be borne by the fan, and additional rigid support is required to bear the load. It should also be noted that, within the range of twice the diameter of the impeller diameter of the air inlet and outlet, try to avoid sudden changes in the elbow or other section of the pipe, which will cause the pipe resistance to increase sharply and affect the fan performance.
- 5. The motor wiring must be carried out by professionals to ensure the authenticity and safety of the wiring, and to avoid the motor being burnt out due to wiring errors. When connecting a three-phase power supply, pay attention to whether the impeller is reversed. If so, correct any two power lines.
- 6. In order to avoid damage to the impeller caused by debris entering the inside of the fan, consider installing corresponding protective parts at the air inlet end during installation.
- 1. Before starting the fan, check whether there are any items in the fan and pipeline that hinder the rotation. If there is any, remove it before starting.
- 2. The machine must be tested before it is officially used, and it can be used formally under the premise of ensuring that the wiring is correct, the fan has no abnormal noise, the power is not overloaded, and the fan rotation direction is consistent with the label.
- 3. Do not start or stop the fan too frequently, otherwise the motor will be easily damaged.
- 4. In order to avoid damage to the fan caused by the vibration of the impeller due to damage to the balance, the impeller must be inspected regularly. If dust and oil are found on the surface of the impeller, it must be cleaned before use.
- 5. If there is abnormal noise or vibration intensified during the operation of the fan, it must be stopped and checked immediately, and it can be restarted after troubleshooting.
- 6. When the fan is restarted without being used for a long time, it is necessary to check whether the connecting parts are firm and put into use after the trial operation is normal.
- 1. The performance parameters of CB series ultra-thin air-conditioning cabinets are the test data under standard conditions (that is, the medium is clean air at standard atmospheric pressure, the temperature is equal to 20 ° C, and the gas density is equal to 1.2Kg / m3). The test method complies with the requirements of Figure 12 Figure B installation method (free air inlet, pipe air outlet) in the AMCA210 standard.
- 2. The noise shown in the performance curve is A-weighted sound pressure level. The data is the air inlet noise (including motor noise) measured at a 1-meter angle from the air inlet at a 45-degree angle when the air inlet of the fan is not connected to the pipe, and the air outlet is connected to the pipe. Above decibels.