What are the refrigerant?
Cooling lines include any hoses or pipes used to transport liquid and gaseous refrigerant via the cooling system. These lines often consist of thin, flexible pipes, although some installation staff can use lines made of solid copper or steel. The refrigerant lines transport the refrigerant between the condensation coil and the fan unit or blower unit, which can be found on air conditioning, thermal pumping and food storage systems.
Every set of refrigerant lines consists of two separate pipes or pipes. The larger of two, known as suction or line line, transports the refrigerant in its gaseous state. The smaller of the two lines, known as the liquid line, carries refrigerant when it is in its liquid state. In addition to a larger diameter, the intake line can also be identified by the presence of insulation, which is usually not used on a liquid line.
Despite their similar appearance, the refrigerant line actually differs from standard water lines severaland key ways. The tubes are torn before sale is cleaned and limited pipes designed for cooling purposes, which ensures that no contaminants enter the system. Water pipes are not subject to the same level of cleaning and restrictions, and therefore on average are not much less than refrigerant pipes. While water wiring is identified by means of their inner diameter, refrigerant lines are sizes using their outer diameter.
Every set of refrigerant pipe can be installed using tin hangers or tape. Some manufacturers also produce special hangers designed to work with these lines. The lines should be placed close to each other, but they should never touch because it could affect the system's performance.
Installation staff must consider a number of factors when choosing the right size and type of refrigerant lines for each system. Running length between capacitor and compressor often determines diameterr lines. The Sizing line can also be influenced by the material used for lines, as well as the desired speed that the refrigerant must be able to maintain in the pipeline.
refrigerant lines that are incorrectly size can cause significant damage to the coolant components. Pipes that are too large will reduce the pressure in the system, which will lead to poor performance. Without the correct pressure level, the refrigerant changes the states at the wrong time, so it is unable to transport thermal energy as intended. Pipes that are too small can lead to excessive pressure that could flood the cooling system.