What Is a Plating Machine?
Vacuum coating machine mainly refers to a type of coating that needs to be performed under a high degree of vacuum, including many types, including vacuum evaporation coating machine, vacuum multi-arc ion coating machine, vacuum intermediate frequency magnetron sputtering coating machine, multifunctional intermediate frequency magnetic control Sputtering multi-arc composite ion coating machine, vacuum optical (electron beam evaporation) coating machine and other vacuum coating equipment. . The main idea is to divide into evaporation and sputtering.
Vacuum plating machine
Right!
- Chinese name
- Vacuum plating machine
- Application range
- Coatings that require higher vacuum
- For example
- Vacuum evaporation coating machine
- Classification
- Evaporation and sputtering
- Machinable materials
- Including: ABS, PS, PP, PC,
- Vacuum coating machine mainly refers to a type of coating that needs to be performed under a high degree of vacuum, including many types, including vacuum evaporation coating machine, vacuum multi-arc ion coating machine, vacuum intermediate frequency magnetron sputtering coating machine, multifunctional intermediate frequency magnetic control Sputtering multi-arc composite ion coating machine, vacuum optical (electron beam evaporation) coating machine and other vacuum coating equipment. . The main idea is to divide into evaporation and sputtering.
- Vacuum coating machine mainly refers to a type of coating that needs to be performed under a high degree of vacuum, including many types, including vacuum evaporation coating machine, vacuum multi-arc ion coating machine, vacuum intermediate frequency magnetron sputtering coating machine, multifunctional intermediate frequency magnetic control Sputtering multi-arc composite ion coating machine, vacuum optical (electron beam evaporation) coating machine and other vacuum coating equipment. . The main idea is to divide into evaporation and sputtering.
- Equipment is widely used. Vacuum evaporation coatings are mainly used in automotive reflective nets, crafts, jewelry, shoes and hats, clocks, lamps, decoration, mobile phones, DVDs, MP3, PDA shells, buttons, cosmetic shells, toys, Christmas gifts and other industries; PVC, nylon , Metal, glass, ceramic, TPU, etc. Vacuum multi-arc ion coating equipment and vacuum magnetron sputtering coating equipment can be used for surface coating of various metals. For example: clock and watch industry (band, case, dial, etc.), hardware industry (sanitary ware, door handle, handle, door Locks, etc.), construction industry (stainless steel plates, stair handrails, columns, etc.), precision mold industry (standard bar molds, forming molds, etc.), tool industry (drills, carbides, milling cutters, broaches, cutter heads) , The automotive industry (pistons, piston rings, alloy wheels, etc.) and pens, glasses, and more.
- 1. The vacuum coating machine should clean the workroom once after completing more than 200 coating procedures. The method is: repeatedly scrub the interior of the vacuum chamber with a saturated solution of caustic soda (NaOH). (Note that the human skin cannot directly contact the caustic soda solution to avoid burns.) The purpose is to make the coated aluminum (AL) react with NaOH. The layer came off and released hydrogen. Then clean the vacuum chamber with clean water and clean the dirt in the fine suction valve with a cloth moistened with gasoline.
- 2. When the rough pump (slip valve pump, rotary vane pump) works continuously for one month (half of the rainy season), new oil needs to be replaced. The method is: unscrew the oil bolt, drain the old oil, and then start the pump for a few seconds, so that the old oil in the pump is completely discharged. Unscrew the oil bolt and add new oil to the rated capacity (oil sight glass observation). For more than half a year of continuous use, the oil cap should be opened when changing the oil, and the dirt inside the box should be cleaned with a cloth.
- 3. The diffusion pump has been used continuously for more than 6 months, the pumping speed is obviously slow, or the operation is improper. Fill the atmosphere, remove the connection water pipe, remove the electric furnace plate, screw out the first-stage nozzle, and first use gasoline to pump the cavity and the pump. Wash the gallbladder again, then wash it with washing powder and water, and then wash it thoroughly with water. After the water evaporates and dry, install the pump bladder, add new diffusion pump oil, and put it back in the body. Connect the water pipe and the electric stove. Disk, you can restart. Before restarting, pay attention to leak detection. The method is: start the maintenance pump and close the door. After a few minutes, observe whether the vacuum degree of the part of the diffusion pump reaches 6X10 Pa. Otherwise, leak detection is required. Check whether there is a sealing rubber ring at the joint or the sealing ring is damaged. Do not heat until the hidden danger of air leakage is eliminated, otherwise the diffusion pump oil will burn the ring and cannot enter the working state.