What is the tester of the vessel?

The container tester is a device that shows whether they are live, neutral and ground wires properly connected to the output socket or power outlet. It contains selectors and indicator lights, which are usually neon bulbs that emit a very small current. Connecting the output from the AC wall (AC) should be correct than the container is certified as safe for use. The testers of the container are also used to verify that the neutral wire is not short -circuited to the ground. This is confirmed, as shown by a good neutral separation indicator. Polarized plugs ensure that connection for live, neutral and soil is consistent so that people cannot connect them in a bad way. There is only one orientation in which the power plug can be inserted into the output of the AC wall. This is a very important, because any adjustment that defeats the polarized nature of the plug and output is a safety risk.

One of the possible faults with the connection of the container is that only one wire is connected to the container. If only one conductor is connected and is a living wire, there is a high risk that people will be electric. Most devices will have a neutral resistance that is relatively low, as well as relatively low neutral resistance to Earth. The Earth is usually associated with conductive parts of the device or equipment of the device. If people again touch the ground units or units without a neutral connection, there is a risk of electricity.

It is possible to use both electrical and electronic test equipment to confirm the correct connection of the AC container. The results can only show the tester of vessels. If there are many testing containers, the Alze tester to use a voltmeter. Voltmeter or multi-sketter can quickly show tension from living to neutral, then to the ground. If these two voltages are not the same, it suggests that there is a live connection and there is no short circuit between neutral and earth.

ground wire and neutral wire are designed to be separate. There are some errors where the neutral wire is short -circuited to the ground conductor on the container. This can complicate efficient energy sources for equipment or equipment. During lightning, the electromagnetic discharge can induce currents into the grounding system. If the neutral is grounded, the input voltage to the device or the device could exceed the safe levels and cause damage that could be prevented from properly connected.

IN OTHER LANGUAGES

Was this article helpful? Thanks for the feedback Thanks for the feedback

How can we help? How can we help?