What Is a Micromanipulator?
The micromanipulator is equipped with the equipment of the microelectrode amplifier. Micro-controllers and micro-manipulators are electrophysiological experimental equipment used to study cell level. They can be used as medical equipment for scientific research and teaching of eight-year students. Good push. The main role of the micromanipulator is to fix the glass microelectrode, and then adjust the microelectrode's stroke within a small range so that it can be effectively inserted into the cell.
Micromanipulator
- This entry lacks an overview map . Supplementing related content makes the entry more complete and can be upgraded quickly. Come on!
- The micromanipulator is equipped with the equipment of the microelectrode amplifier. Micro-controllers and micro-manipulators are used for research
- The micromanipulator is equipped with the equipment of the microelectrode amplifier. Micro-controllers and micro-manipulators are used for research
- 1. Accuracy: 5m;
- 2. Four-axis travel: 25mm;
- 3.R axis: + 90 ° ~ -90 ° adjustable;
- 1. Beautiful design and easy operation
- 2. In line with the latest international trends
- 3, 5-dimensional adjustment
- 4. Provide matching automatic regulator for users to choose
- I. Micromanipulator 5-dimensional adjustment function:
- X-axis coarse adjustment, X-axis fine view, Y-axis adjustment, Z-axis first-level two-level three-level adjustment, vertical rotation lock bolt adjustment, horizontal rotation adjustment;
- 2. Micro-manipulator electric adjustment:
- The micro-manipulator has an electric adjustment function, which can realize automatic adjustment of various functions in the Z-axis direction, such as specifying a forward stroke, single-step forward, etc. Its minimum control accuracy can reach 1 & micro; m. As shown below:
- 1. LCD display: display the setting parameters and working status of the device.
- 2. Parameter setting area: The parameter setting area can set the stroke and speed of the micromanipulator on the Z axis.
- "Speed +" and "Speed-" buttons adjust the movement speed of the micro operation.
- 1. Protect the device from impact, impact, or strong vibration.
- 2. Clean. Unplug the power plug before cleaning. Do not use strong detergent, banana water, gasoline, abrasive powder and metal brushes to clean any part of the product. Please use a soft cloth and neutral cleaning solution to clean it. After cleaning, please dry it in time to keep the instrument dry.
- 3. The slots and openings on the back or side of the cabinet are used to maintain ventilation. Never block or cover them. Do not place near radiators or heat sources.
- 4. Do not push any objects into the product, and do not allow any liquid to flow into it.
- 5. If not used for a long time, unplug the power plug and place it in a dry and ventilated environment without corrosive gas.